Oral glucose tolerance test (OGTT) in mice
This protocol adopts the protocols.io Oral Glucose Tolerance Test in Mouse v1. Mice are fasted for 4–6 hours, weighed, and given oral glucose at 1 g/kg (0.5 g/kg after at least 4 weeks of high-fat diet). Blood glucose is measured before and at 15, 30, 60, 90 and 120 minutes after the load, with tail-vein plasma collected at selected time points for insulin measurement. The record describes the assay procedure, not executed disease-model results.
Scope and method
Sample:mouse blood and plasma
Bill of materials (BOM)
| Step | Material | Role | Amount | Required / optional | SKU / specification |
|---|---|---|---|---|---|
| Plasma insulin assay | STELLUX Chemi Rodent Insulin ELISA(ALPCO 80-INSMR-CH01) | Quantitative plasma insulin · ALPCO 80-INSMR-CH01 original manufacturer kit; each batch includes kit standards and quality controls; perform calibration, incubation, washing, and chemiluminescence plate reading according to the instructions. | Each plasma sample was measured using the loading volume specified in the ALPCO 80-INSMR-CH01 instructions; the source protocols.io procedure did not list a specific volume. | Required | REF-alpco-80-insmr-ch01 |
| Oral glucose load | 70% ethanol | Disinfection of the tail vein blood collection site · 70% ethanol, used for disinfection of the blood collection site according to the source protocol; avoid ethanol contact with the reaction area of the blood glucose test strip. | Wipe the tail vein blood collection site with gauze moistened with 70% ethanol | Required | Available for inquiry |
| Oral glucose load | D-glucose | Oral glucose load · Sterile 50% glucose solution (25 g/50 mL), administered by oral gavage according to the source protocol; the dose was calculated by body weight and kept consistent throughout the study. | 1 g/kg (50% glucose solution 2 µL/g body weight; for high-fat diet ≥4 weeks, 0.5 g/kg, 1 µL/g) | Required | Available for inquiry |
| Oral glucose load | Blood glucose test strips | Blood glucose measurement · OneTouch Ultra blood glucose test strips are matched with the OneTouch Ultra 2 blood glucose meter, stored sealed and moisture-proof, and used within the expiration date. | 1 entry per time point | Required | Available for inquiry |
Inquire about the whole BOM
Bulk pricing and availability inquiry
Submitting an inquiry does not place an order or confirm a purchase.
Procedure
Fasting
Fasting begins first thing in the morning (around 9am). Fast mice for 4-6 hours before OGTT begins. Transfer mice to clean cage and wire top. Keep water bottles during the fasting period. 1. If using High Fat diet (HFD), save food to give back at the end of the OGTT. 1. mark tails with a sharpie for easier identification during OGTT.
Oral glucose load
Weigh mouse to obtain body weight for dose calculations. Calculate bolus dose of glucose (1g/kg). Weight of mouse (g) x 2 = ul sterile glucose (50% dextrose) solution *If using HFD for 4 weeks or more, use 0.5g/kg (weight of mouse (g) x 1 = ul sterile glucose (50% dextrose) solution)
Oral glucose load
Prepare syringes using 1cc syringe and 18G oral gavage needle. Load all syringes with calculated glucose dose and position in front of home cage.
Oral glucose load
Prior to the delivery of the sterile glucose (50% dextrose) solution, a time “zero” blood glucose level must be measured. Restrain mouse and clean tail with 70% ethanol/gauze. Extract a small amount of blood from the tail vein onto One Touch Ultra blood glucose strips used with the One Touch Ultra 2 blood glucose monitoring system. Blood can be collected into microvette tubes that can be used to extract plasma which can be assayed for plasma insulin (see step 9 for plasma collection). Microvette tubes are blood collection tubes with a capillary. Tap tube until all the blood is collected in the tube. Place on ice until plasma collection.
Oral glucose load
Administer the correct dose of sterile glucose (50% dextrose) solution using the syringe and gavage needle. - Restraint of the Mouse, avoiding an excessively tight grip of the mouse, as this will induce a panic response. Ensure that the mouse cannot bite you and cannot move its head. - Gravity alone should be used to move the cannula down the esophagus. While gliding the cannula, rotate slightly as the cannula goes past the epiglottis and into the esophagus.The mouse should swallow the cannula, and this can be observed. - Inject the fluid slowly. - The cannula is then gently removed and the animal is returned to its cage.
Oral glucose load
Begin timing from the point of successfully delivering the sterile glucose (50% dextrose) solution.
Oral glucose load
Test and record the blood glucose level (see step 4) at 15, 30, 60, 90 and 120 minutes after the initial glucose delivery. Record each value and the condition of the animal on the Glucose Tolerance Test record sheet. Extract a small amount of blood from the tail vein at 15, 30, 60 and 120 minutes for plasma; skip blood collection at 90 minutes to ensure not to exceed 0.007 ml blood/ g body weight.
Oral glucose load
Return food and environmental enrichments to cages.
Plasma collection
Place tubes into pre-chilled centrifuge. Centrifguge for 2 mins at 2000 rpm. 00:02:00 4 °C
Plasma collection
Remove the callipary-lid and dispose in biohazard bin. Place the base lid and seal the microvette (click position).
Plasma collection
Centrifuge at 4°C for 10 mins at 10 000 rpm. 00:10:00 4 °C
Plasma collection
Using a pipette, transfer the plasma (top transparent layer) to a clean and labelled tube. Store plasma samples at -20°C until assayed.
Plasma insulin assay
Assay plasma insulin with the STELLUX Chemi Rodent Insulin ELISA kit (ALPCO #80-INSMR-CH01) according to the manufacturer's protocol. Include the kit standards and quality controls in each assay and read the plate by the kit's chemiluminescence procedure.
Quality control and readouts
Fasting time, glucose dose and route of administration are kept consistent throughout the study; the glucometer and test strips are matched and calibrated and stored according to the manufacturer's requirements; body weight, time points and readings are recorded for each animal; the total volume of tail vein blood does not exceed 0.007 mL/g body weight, and the source protocol skips blood collection at 90 minutes to meet this limit; plasma centrifugation and storage follow the protocol conditions.
Blood glucose time series at baseline and 15, 30, 60, 90 and 120 minutes after the load; the area under the blood glucose curve can be calculated. Plasma insulin results are interpreted according to the calibration and range of the ELISA used.
- Study design
- A tolerance test in which mice receive a glucose load by oral gavage. After a 4–6 hour fast, 50% glucose solution is given at 1 g/kg on a normal diet or 0.5 g/kg after more than 4 weeks of high-fat diet; blood glucose is measured before the load and 15, 30, 60, 90 and 120 minutes after it. Groups and sample sizes are determined by the specific study design, and this protocol does not presuppose any experimental grouping.
References
- Nancy Smith, Mourad Ferdaoussi, Haopeng Lin, Patrick Macdonald. Oral Glucose Tolerance Test in Mouse. protocols.io. https://doi.org/10.17504/protocols.io.ujjeukn · DOI: 10.17504/protocols.io.ujjeukn
- Benedé-Ubieto R, Estévez-Vázquez O, Ramadori P, Cubero FJ, Nevzorova YA. Guidelines and Considerations for Metabolic Tolerance Tests in Mice. Diabetes Metab Syndr Obes. 2020;13:439-450. PMID 32110077. doi:10.2147/DMSO.S234665 · DOI: 10.2147/DMSO.S234665
Databases and strain resources
- ALPCO. STELLUX Chemi Rodent Insulin ELISA (Catalog #80-INSMR-CH01) instructions. · https://s3.amazonaws.com/alpco-docs/80/80-INSMR-CH01.pdf